Parameters ASDA-B3 P1.006 is the low-pass filter and P1.059 is the moving filter. The difference between them is that the moving filter can smooth the beginning and end of the step command, while the low-pass filter can only 8 smooth the command at the end. Therefore, if the speed loop receives the command from the controller for the position control loop, then the low-pass filter is recommended. If the setting is only for the speed control, then use the moving filter for better smoothing. Original step analog Speed command Holding time Command that has gone through analog speed linear filtering Settings: Sets the level of friction compensation.
For the percentage of rated torque, set the value to 0 to disable the function and set the value to 1 or above to enable the function. Settings: Sets the smoothing constant of friction compensation. 8-54 P 1.060 - Reserved P 1.061 Address: 017CH P1.062 Percentage of friction compensation 017DH Default: 0 Control mode: PT / PR / S / Sz Unit: % Setting range: 0 - 100 Format: DEC Data size: 16-bit Address: 017EH P1.063 Constant of friction compensation 017FH Default: 1 Control mode: PT / PR / S / Sz Unit: ms Setting range: 1 - 1000 Format: DEC Data size: 16-bit