Delta Electronics — P1.xxx Basic parameters

ASDA-B3 Parameters Original Position command Holding time 8 Command that has gone through moving filter Settings: Y Z U X Reserved Reserved  Y: selection of OA / OB / OZ output source 0: output source is from the encoder connected to CN2 1: reserved 2: output source is the pulse command from CN1 (If P1.097 = 0, the output ratio has to be 1 : 1. If you need to change the output ratio, refer to the settings of P1.046 and P1.097.) Settings: The reference value of the filtered maximum speed which is actually input to the motor. 8-57 P1 .069 - Reserved P 1.073 Address: 0194H P1.074 Output source of OA / OB / OZ 0195H Default: 0x0000 Control mode: PT Unit: - Setting range: 0x0000 - 0x0030 Format:

HEX Data size: 16-bit X Reserved Z Y Selection of OA / OB / OZ output source U P1.075 Reserved Address: 0198H P1.076▲ Maximum speed for encoder output (OA, OB) 0199H Default: 5500 Control mode: All Unit: rpm Setting range: 0 - 6000 (0: disable this function) Format: DEC Data size: 16-bit