ASDA-B3 Parameters to find the Z pulse as the origin. 8 Torque level detection Torque curve when the servo searches for P1.087 the hard stop Start point Torque curve when the servo searches for Z pulse Z pulse Note: the actual maximum torque output of the motor is 10% greater than the detected torque level (P1.087). For example: set P1.087 to 50%, then the maximum torque output of the motor is 60%. Settings: The setting of the level reached timer for the torque homing mode. Refer to P1.087 for the timing diagram of torque homing mode. Settings: Anti-resonance frequency for the first set of low frequency vibration elimination. Use this function in flexible machines with low rigidity.

The definition of a flexible machine is one for which when the target position is reached, due to lack of rigidity, the machine vibrates and needs more time to become stable. B3 provides two sets of vibration elimination. The first set is P1.089 - P1.091 and the second set is P1.092 - P1.094. The vibration elimination setting must be obtained through the system module and enabling the low-frequency analysis option is needed. Vibration elimination takes effect only when the two dimensional control function is enabled (P2.094 [Bit 12] = 1).

After enabling the two dimensional control function, enable the first set of vibration elimination with P2.094 [Bit 8] and the second set with P2.094 [Bit 9]. 8-59 Protector Level reached timer P1.088 Maximum torque output 10% n Protector Level reached timer P1.088 Maximum torque output n Address: 01B0H P1.088 Torque homing - level reached timer 01B1H Default: 2000 Control mode: PR Unit: ms Setting range: 2 - 2000 Format: DEC Data size: 16-bit First set of vibration elimination - anti-resonance Address: 01B2H P1.089 frequency 01B3H Default: 4000 Control mode: PT / PR Unit: 0.1 Hz Setting range: 10 - 4000 Format: DEC Data size: 16-bit