Delta Electronics — P1.xxx Basic parameters

Parameters ASDA-B3 8 Settings: When the disconnection detection protection (UVW) function is enabled (P2.065 [Bit 9] = 1), select the detection response time with this parameter. Set P1.098 to 0 to use the servo's default response time. When P1.098 is not set to 0, the setting range should be between 100 and 800 as the detection response time. Note: 1. If it is necessary to shorten the response time, it is recommended that you use this parameter. 2. When the servo is on and the motor does not move (servo drive has not issued the command), it is recommended that you set this parameter if disconnection detection is needed. Settings:

When you set 6 for the monitor source of P0.003 [YX], then the analog monitor output voltage refers to the voltage value of P1.101. Note: the analog monitor output voltage should be within the range of -8V to 8V. Settings: When you set 7 for the monitor source of P0.003 [YX], then the analog monitor output voltage refers to the voltage value of P1.102. Note: the analog monitor output voltage should be within the range of -8V to 8V. 8-62 Address: 01C4H P1.098 Disconnection detection protection (UVW) response time 01C5H Default: 0 Control mode: All Unit: ms Setting range: 0, 100 - 800 Format: DEC Data size: 16-bit P 1.099 - Reserved P 1.100 Address:

01CAH P1.101■ Analog monitor output voltage 1 01CBH Default: 0 Control mode: All Unit: mV Setting range: -10000 to 10000 Format: DEC Data size: 16-bit Address: 01CCH P1.102■ Analog monitor output voltage 2 01CDH Default: 0 Control mode: All Unit: mV Setting range: -10000 to 10000 Format: DEC Data size: 16-bit