Delta Electronics — P1.xxx Basic parameters

ASDA-B3 Parameters 8 This function is to protect the motor from overspeeding, which can be applied to all control modes. Settings: When the filtered motor speed exceeds this set speed, AL056 is triggered. Settings: Sets the torque limit for one of the motor operation directions. If the value of P1.112 is smaller than the values of P1.012 - P1.014, the torque limit changes according to the setting of P1.112. Otherwise, the torque limit remains unchanged . 8-63 P1.103 - Reserved P1.110 Address: 01DEH P1.111 Overspeed protection level 01DFH Default: Maximum motor speed x 1.1 Control mode: Unit: rpm Setting range: Format: DEC Data size: Address:

01F0H P1.112 Single-direction torque limit 01F1H Default: 500 Control mode: Unit: % Setting range: Format: DEC Data size: