Delta Electronics — P2.xxx Extension parameters

Parameters ASDA-B3 P2.xxx Extension parameters 8 Settings: Increasing the position control gain can enhance the position response and reduce the deviation in position control. If you set the value too high, it may cause vibration and noise. Settings: Adjust the rate of change for the position control gain according to the gain switching condition. Settings: If the position control command changes position smoothly, increasing the gain value can reduce the position following errors. If it does not change smoothly, decreasing the gain value can reduce the mechanical vibration during operation. Note:

this gain parameter is disabled when the two dimensional control function is on (P2.094 [Bit 12] = 1). Settings: If the position control command changes position smoothly, decreasing the smoothing constant value can reduce the position following errors. If it does not change smoothly, increasing the smoothing constant value can reduce the mechanical vibration during operation. 8-64 Address: 0200H P2.000 Position control gain 0201H Default: 35 Control mode: PT / PR Unit: rad/s Setting range: 0 - 2047 Format: DEC Data size: 16-bit Address: 0202H P2.001 Position control gain rate of change 0203H Default: 100 Control mode: PT / PR Unit: % Setting range: 10 - 500 Format: DEC Data size:

16-bit Address: 0204H P2.002 Position feed forward gain 0205H Default: 50 Control mode: PT / PR Unit: % Setting range: 0 - 100 Format: DEC Data size: 16-bit Address: 0206H P2.003 Position feed forward gain smoothing constant 0207H Default: 5 Control mode: PT / PR Unit: ms Setting range: 2 - 100 Format: DEC Data size: 16-bit