Delta Electronics — P2.xxx Extension parameters

ASDA-B3 Parameters 8 Settings: Increasing the speed control gain can enhance the speed response. If you set the value too high, it may cause vibration and noise. Settings: Adjust the rate of change for the speed control gain according to the gain switching condition. Settings: Increasing the value of the integral speed control can enhance the speed response and reduce the deviation in speed control. If you set the value too high, it may cause vibration and noise. Settings: If the speed control command changes speed smoothly, increasing the gain value can reduce the speed following errors.

If it does not change smoothly, decreasing the gain value can reduce the mechanical vibration during operation. 8-65 Address: 0208H P2.004 Speed control gain 0209H Default: 500 Control mode: Unit: rad/s Setting range: Format: DEC Data size: Address: 020AH P2.005 Speed control gain rate of change 020BH Default: 100 Control mode: All Unit: % Setting range: 10 - 500 Format: DEC Data size: 16-bit Address: 020CH P2.006 Speed integral compensation 020DH Default: 100 Control mode: All Unit: rad/s Setting range: 0 - 1023 Format: DEC Data size: 16-bit Address: 020EH P2.007 Speed feed forward gain 020FH Default: 0 Control mode: All Unit: % Setting range: 0 - 100 Format: DEC Data size: 16-bit