Parameters ASDA-B3 8 Settings: Refer to the description of P2.018. Settings: Refer to the description of P2.018. Settings: The first setting for resonance frequency. This function is disabled if P2.024 is 0. P2.043 and P2.044 are the second Notch filter parameters. Settings: The first Notch filter attenuation level. For example, an attenuation level of 5 indicates -5 dB. 8-70 Address: 022AH P2.021 DO4 functional planning 022BH 0x0105 (B3-L) 0x0100 (B3-F, E, M) Default: Control mode: - Unit: Setting range: Format: HEX Data size: Address: 022CH P2.022 DO5 functional planning 022DH 0x0007 (B3-L) 0x0100 (B3-F, E, M) All Default: Control mode: - 0x0000 - 0x013F (last two codes are DO codes) Unit:
Setting range: Format: HEX Data size: 16-bit Address: 022EH P2.023 Notch filter frequency (1) 022FH Default: 1000 Control mode: All Unit: Hz Setting range: 50 - 5000 Format: DEC Data size: 16-bit Address: 0230H P2.024 Notch filter attenuation level (1) 0231H Default: 0 Control mode: All Unit: -dB Setting range: 0 - 40 (0: disable this function) Format: DEC Data size: 16-bit