ASDA-B3 Parameters 8 Settings: Sets the time constant for the low-pass filter for resonance suppression. This function is disabled if P2.025 is 0. Settings: Increasing this parameter can increase the damping of the speed loop and reduce the speed loop response. Setting the value of P2.026 to equal P2.006 is recommended. See the following for setting P2.026: 1. In Speed mode, increase the value of this parameter to reduce speed overshoot. 2. In Position mode, decrease the value of this parameter to reduce position overshoot. Note: this gain parameter is disabled when the two dimensional control function is on (P2.094 [Bit 12] = 1). Settings: Y Z U X X: gain switching condition 8-71 Address:
0232H P2.025 Resonance suppression low-pass filter 0233H Operation Panel / software Communication All Control mode: interface: Default: 1.0 10 Data size: 16-bit Unit: 1 ms 0.1 ms - - Setting range: 0.0 - 100.0 0 - 1000 - - Format: One decimal DEC - - Example: 1.5 = 1.5 ms 15 = 1.5 ms - - Address: 0234H P2.026 Anti-interference gain 0235H Default: 0 Control mode: All Unit: rad/s Setting range: 0 - 1023 Format: DEC Data size: 16-bit Address: 0236H P2.027 Gain switching condition and method selection 0237H Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0018 Format: HEX Data size:
16-bit X Gain switching condition Z Reserved Y Gain switching method U Reserved X Function 0 Disable gain switching function 1 Signal of gain switching (DI.GAINUP) is on