Delta Electronics — P2.xxx Extension parameters

Parameters ASDA-B3 8 Settings: The servo drive provides three gain adjustment modes for fine tuning. You can then easily complete tuning by increasing or decreasing the bandwidth response level (P2.031). Follow the tuning procedure in Section 5.1. Note: when the two dimensional control function is disabled (P2.094 [Bit 12] = 0), the effect of gain adjustment mode 3 is equivalent to that of gain adjustment mode 2, so setting P2.089 is invalid in that scenario. 8-74 Address: 0240H P2.032 Gain adjustment mode 0241H Default: 0x0001 0x0000 (B3-F) Control mode: All Unit: - Setting range: 0x0000 - 0x0004 Format: HEX Data size:

16-bit Setting value 0 1 2 3 4 Setting Adjustment mode Inertia estimation Parameter value Manual Auto Manual Fixed set value of P1.037 P1.037, P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.089, P2.098, P2.099, P2.101, P2.102 N/A Gain adjustment mode 1 Real-time estimation P2.031 P1.037, P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.089, P2.098, P2.099, P2.101, P2.102 Gain adjustment mode 2 Fixed set value of P1.037 P1.037 P2.031 P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.089, P2.098, P2.099, P2.101, P2.102 Gain adjustment mode 3 (only when two dimensional control function is enabled) Fixed set value of P1.037 P1.037 P2.031 P2.089 P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.098, P2.099, P2.101, P2.102 Gain adjustment mode 4 Reset to default gain value