Delta Electronics — P2.xxx Extension parameters

ASDA-B3 Parameters 8 Settings: In Speed mode, this parameter sets the acceptable difference between the command speed and the feedback speed. If the difference is greater than this value, AL007 occurs. Settings: In Position mode, this parameter sets the condition of acceptable difference between the command position and the feedback position. If the difference is greater than this value, AL009 occurs. Settings: Refer to the description of P2.010. There is no physical pin for DI9 on all models. DI9 is a virtual digital input which you can use when the number of physical DI points is insufficient and trigger through commuicaiton.

You can set this virtual DI for a normally closed contact if the DI has to switch on as soon as power is applied, such as DI.SON. 8-75 P2.033 Reserved Address: 0244H P2.034 Speed command error warning 0245H Default: 5000 Control mode: Unit: rpm Setting range: Format: DEC Data size: Address: 0246H P2.035 Excessive deviation of Position command warning 0247H Default: 50331648 Control mode: PT / PR Unit: pulse Setting range: 1 - 1677721600 Format: DEC Data size: 32-bit Address: 0248H P2.036 DI9 functional planning 0249H Default: 0x0100 Control mode: All - 0x0000 - 0x015F (last two codes are DI codes) Unit: Setting range: Format: HEX Data size: 16-bit