Parameters ASDA-B3 8 Settings: The third setting for resonance frequency. This function is disabled if P2.046 is 0. Settings: The third Notch filter attenuation level. A value of 5 indicates -5 dB. Settings: Y Z U X X: auto resonance suppression function 0: disable auto resonance suppression. After the function is disabled, the existing resonance 1: auto resonance suppression mode 1; when the servo determines it is stable* 2 , the servo stores suppression parameter values do not change. the resonance suppression points to EEPROM (non-volatile memory for parameters) and disables the auto resonance suppression function (X = 0).
Before the servo is stable, (1) If you cycle power on the servo drive, the found resonance suppression points are lost and will not be saved. The servo searches for the resonance suppression points again. (2) If you switch the setting of X from 1 to 0, the known resonance suppression points will be stored to EEPROM. (3) If you keep the setting of X as 1, the known resonance suppression points will not be cleared, but they are not written to EEPROM yet. They are written to EEPROM when the servo determines it is stable. 8-78 Address: 025AH P2.045 Notch filter frequency (3) 025BH Default: 1000 Control mode: All Unit: Hz Setting range: 50 - 5000 Format: DEC Data size: 16-bit Address:
025CH P2.046 Notch filter attenuation level (3) 025DH Default: 0 Control mode: All Unit: -dB Setting range: 0 - 40 (0: disable this function) Format: DEC Data size: 16-bit Address: 025EH P2.047 Auto resonance suppression mode 025FH Default: 0x0001 Control mode: All Unit: - Setting range: 0x0000 - 0x01F2 Format: HEX Data size: 16-bit X Auto resonance suppression function Z Fixed resonance suppression parameter Y Fixed resonance suppression parameter U Reserved