ASDA-B3 Parameters  Z*: index coordinates function setting when overflow occurs 0: index coordinates are lost when overflow occurs. 1: index coordinates are not affected by overflow, but absolute coordinates are not retained. 8 Note: this function is coming soon. Settings: Bit Bit Settings: When P2.071 is 1, the current absolute position of the encoder is the home position. Set P2.008 to 271 and then you can enable this function. Settings: Increasing this gain speeds up the responsiveness of the Position command and shortens the tuning time, but when the gain is too large, it causes position overshoot which leads to machine jitter. Note:

enable the two-degrees-of-freedom control function (P2.094 [Bit 12] = 1) before adjusting this parameter. 8-87 Address: 028CH P2.070 Read data selection 028DH Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0007 Format: HEX Data size: 16-bit 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 Bit Function Description Bit 0 DI/DO data unit setting 0: PUU. 1: pulse. Bit 1 Communication data unit setting 0: PUU. 1: pulse. Bit 2 Overflow warning setting 0: overflow warning, including AL289 (PUU) and AL062 (pulse). 1: no overflow warning. Bit 3 - Bit 15 Reserved - Address: 028EH P2.071■ Absolute position homing 028FH Default: 0x0000 Control mode: All Unit: - Setting range:

0x0000 - 0x0001 Format: HEX Data size: 16-bit P 2.072 - Reserved P2.088 Address: 02B2H P2.089 Command response gain 02B3H Default: 25 Control mode: PT / PR Unit: rad/s Setting range: 1 - 2000 Format: DEC Data size: 16-bit