Delta Electronics — 10.3.2 Pulse number

Absolute System ASDA-B3 10.3.2 Pulse number When the motor is running in the clockwise direction, the cycle number is expressed as a 10 negative value. When the motor runs in the counterclockwise direction, the cycle number is expressed as a positive value. The range of the number of rotations is between -32768 and +32767, and AL062 occurs once the number exceeds the range. To clear the alarm, re-establish the absolute origin coordinates. If P2.070 has been set to ignore the AL062 alarm, then the system shows no error.

If the system is operating in the counterclockwise direction and reaches 32,767 turns, the value jumps to -32768 once it reaches the target position in the next cycle, and the value keeps increasing from -32768 to 32767. When the system is operating in the clockwise direction and reaches -32,768 turns, the value jumps to 32767 once it reaches the target position in the next cycle, and the value keeps decreasing from 32767 to -32768. In addition to the cycle counter, there are 16,777,216 pulses (0 - 16777215) in one rotation. Pay attention to the motor's running direction. You can read the cycle number and the pulse number either with communication or DI/DO.

Pulse number = m (cycle number) x 16777216 + pulse number (0 - 16777215). The conversions between pulse number and PUU are as follows: When P1.001.Z = 0, then the PUU number when power on = pulse number x P1.045 P1.044 + P6.001. When P1.001.Z = 1, then the PUU number when power on = (-1) x pulse number x P1.045 P1.044 + P6.001. Cycle number P0.051 (16777216-1) Pulse 0 CCW CW Figure 10.3.2.1 Absolute position for pulse number 10-14 Pulse number in one turn m = -2 m = -1 m = 0 P0.052 m = 1 . . . . . . 0 - 16777 215 0 - 16777215 0 - 16777215 0 - 16777215 0 - 16777215 0 - 167 77215 Origin