ASDA-B3 CANopen Mode Heartbeat The Heartbeat mechanism is mainly to enable the producer to periodically send packets to the consumer. The producer can be a controller or servo drive; on the other hand, a controller or 11 servo drive can also be the consumer. If you use the servo drive as the consumer and the controller to send the heartbeat, you need to set the heartbeat receiving time (OD 1016h) of the servo drive. When the servo drive does not receive the heartbeat signal within the receiving time, the heartbeat event is triggered, meaning AL180 is triggered. Consumer heartbeat time (OD 1016h) is defined as the time the servo drive expects to receive a heartbeat.
For the setting, consumer heartbeat time (OD 1016h) must be greater than the producer heartbeat time. The producer time is set by the controller. Due to delays and other uncontrollable external factors in transmitting the heartbeat, you must retain a tolerance margin value. COB-ID = 700h+Node-ID The S code is described as follows: If you want to use the servo drive as the producer, then the heartbeat is sent by the drive and you need to set the producer heartbeat time (OD 1017h). Set the consumer heartbeat time for the controller, which must be greater than the producer heartbeat time.
When the controller does not receive the heartbeat signal within the receiving time, it triggers the heartbeat event which corresponds to the alarm defined by the controller. 11-15 Heartbeat producer Heartbeat producer time Heartbeat producer Example for Node-ID = 1 701h S 701h S No signal Heartbeat consumer Heartbeat consumer time (OD 1006h) Heartbeat consumer Heartbeat consumer time (OD 1006h) AL180 701h S S Function 0 Bootup 4 Stopped 5 Operational 127 Pre-operational