Delta Electronics — 11.3.1 Profile Position Mode

CANopen Mode ASDA-B3  When 6040h Bit 5 is set to 1, the command to take immediate effect is enabled (only valid in Profile Position Mode). 11 If the command to take immediate effect is enabled, when the current motion command is in execution (not yet complete), the servo immediately interrupts the current command and executes the new command once the servo receives a new triggered command. Position 50000 PUU Target position (607Ah) 1 triggered (6040h Bit 4) Command 0 Velocity actual value (606Ch) Execute current position Set-point acknowledge (6041h Bit 12) 1 0 Target reached (6041h Bit 10) 1 0 Relevant object list Note: for more details, refer to Section 11.4.3 Details of objects.

11-20 20000 PUU Time eed 60000 PUU/s 30000 PUU/s Index Name Data type Access 6040h Controlword UNSIGNED16 RW 6041h Statusword UNSIGNED16 RO 6060h Modes of operation INTEGER8 RW 6061h Modes of operation display INTEGER8 RO 6062h Position demand value [PUU] INTEGER32 RO 6063h Position actual internal value INTEGER32 RO 6064h Position actual value INTEGER32 RO 6065h Following error window UNSIGNED32 RW 6067h Position window UNSIGNED32 RW 6068h Position window time UNSIGNED16 RW 607Ah Target position INTEGER32 RW 6081h Profile velocity UNSIGNED32 RW 6083h Profile acceleration UNSIGNED32 RW 6084h Profile deceleration UNSIGNED32 RW 6093h Position factor UNSIGNED32 RW 60F4h Following error actual value INTEGER32 RO 60FCh Position demand value INTEGER32 RO