Delta Electronics — 12.2 Causes and corrective actions

ASDA-B3 Troubleshooting AL072 Encoder overspeed 3. Use shielded cable for the encoder, pull out the shielded mesh, and ground it. Checking method and corrective action 4. Check the motor speed and make sure it is within the rated range. 12 If the issue persists, send your servo motor back to the distributor or contact Delta. How to clear the alarm? Cycle power on the servo drive. 12-27 AL073 Encoder memory error Trigger condition and cause An error occurs when the encoder is reading data from or writing data to EEPROM. Checking method and corrective action 1. Check if the motor is properly grounded. Make sure the power cable is grounded to the servo drive heat sink. 2.

Make sure the encoder signal cable is separated from the power supply or any high-current cables to avoid interference. 3. Use shielded cable for the encoder, pull out the shielded mesh, and ground it. 4. Check the motor speed and make sure it is within the rated range. If the issue persists, send your servo motor back to the distributor or contact Delta. How to clear the alarm? Cycle power on the servo drive. AL074 Encoder single-turn absolute position error Trigger condition and cause The single-turn position in the encoder is in error. Checking method and corrective action 1. Check if the motor is properly grounded. Make sure the power cable is grounded to the servo drive heat sink. 2.

Make sure the encoder signal cable is separated from the power supply or any high-current cables to avoid interference. 3. Use shielded cable for the encoder, pull out the shielded mesh, and ground it. 4. Check the motor speed and make sure it is within the rated range. If the issue persists, send your servo motor back to the distributor or contact Delta. How to clear the alarm? Cycle power on the servo drive.