Delta Electronics — 12.2 Causes and corrective actions

ASDA-B3 Troubleshooting 12 12-31 AL085 Regeneration error Trigger condition and cause Condition: regeneration control error. Cause: regenerative resistor is not operating, but the regenerative voltage remains at 400V for a period of time. Checking method and corrective action Check the connections for the regenerative resistor, re-calculate the value for the regenerative resistor, and reset the values of P1.052 and P1.053. If this does not clear the alarm, send your servo drive back to Delta. How to clear the alarm? DI.ARST AL086 Input voltage is too high Trigger condition and cause Condition:

when the servo drive detects no regenerative power, but other energy (such as interference) is input to the servo drive, or the input voltage is higher than the allowable rated voltage. Cause: 1. Other energy (such as interference) is input to the servo drive or the input voltage is higher than the allowable rated voltage. 2. Malfunction of the servo drive hardware. Checking method and corrective action 1. Use a voltmeter to measure if the input voltage from the power supply is within the allowable rated voltage (refer to Appendix A Specifications). If the input voltage exceeds the rated range, remove the interference source.

If you cannot eliminate the interference, the interference can be consumed with an external resistor by setting P2.065 [Bit 3] to 0 and P2.094 [Bit 4] to 0. 2. If the voltmeter detects that the voltage input from the main circuit is within the allowable rated voltage but the issue persists, then the servo drive may be malfunctioning. How to clear the alarm? 1. Use the correct voltage source or connect the voltage regulator in series. 2. Send your servo drive back to the distributor or contact Delta. AL088 Servo function operational warning Trigger condition and cause Condition: too many motor control functions on the servo drive are enabled. Cause: servo function operational warning.

Checking method and corrective action If using a filter, see if using this filter is necessary.