ASDA-B3 Troubleshooting AL3CF Emergency stop This alarm occurs after AL35F is triggered and when the motor speed has Trigger condition and cause decelerated to 0. 12 Check if any of the parameters P2.010 - P2.017 and P2.036 - P2.040 is set to Checking method and corrective action DI(0x47) and is triggered. How to clear the alarm? Cycle power on the servo drive. 12-45 AL3E1 Communication synchronization fails Trigger condition and cause Condition: the communication synchronization with the controller fails in IP mode. Cause: communication synchronization fails. Checking method and corrective action 1. Make sure the communication between the servo drive and controller is good. 2.
After eliminating any problems that you find, allow the controller to re-send the synchronization signal and ensure that it is sent successfully. 3. Modify the setting of P3.009 (the default setting is suggested). How to clear the alarm? NMT: reset node or 0x6040 fault reset. AL3E2 Communication synchronization signal is sent too soon Trigger condition and cause Condition: the synchronization signal is received too early. Cause: the communication synchronization signal is sent too soon. Checking method and corrective action 1. Make sure the setting of synchronization cycle (0x1006) is identical to that of the controller. 2. Modify the synchronization error range setting (P3.009.U). 3.
Ensure the correct time sequence of sending packets from the controller. A drift or delay in packet sending time causes synchronization failure. How to clear the alarm? NMT: reset node or 0x6040 fault reset.