Troubleshooting ASDA-B3 12 12-46 AL3E3 Communication synchronization signal timeout Trigger condition and cause Condition: the communication synchronization with the controller fails in IP mode. Cause: timeout of synchronization signal. Checking method and corrective action 1. Make sure the communication between the servo drive and controller is good. 2. Make sure the setting of synchronization cycle (0x1006) is identical to that of the controller. 3. Modify the synchronization error range setting (P3.009.U). (For -M and -F models.) 4. Modify the setting of IP command timeout (P3.022.XY). (For -E models.) 5. Ensure the correct time sequence of sending packets from the controller.
A drift or delay in packet sending time causes synchronization failure. How to clear the alarm? NMT: reset node or 0x6040 fault reset. AL3F1 Communication type absolute position command error Trigger condition and cause Condition: the bus communication type (CANopen, DMCNET, and EtherCAT) servo is in combination with an incremental motor, and when the position overflow occurs and the absolute origin coordinates have not been established, the absolute positioning command is issued. Cause: 1. The absolute origin coordinates are not established. 2. Overflow occurs since the motor keeps rotating in the same direction.
Checking method and corrective action Establish the absolute origin coordinates. How to clear the alarm? Establish the absolute origin coordinates. AL400 Indexing coordinate setting error Trigger condition and cause Condition: the offset value of the motor within 1 ms exceeds the setting value of P2.052 (Indexing coordinates scale). Cause: the value of P2.052 is set too low. Checking method and corrective action Check if the setting value of P2.052 exceeds the range. How to clear the alarm? DI.ARST