Troubleshooting ASDA-B3 12 12-48 AL502 STO B lost (signal loss or signal error) _ Trigger condition and cause Loss of STO B signal or STO A and STO B signals are not synchronized for _ _ _ more than 1 second. Checking method and corrective action Make sure the wiring of STO B is correct. _ How to clear the alarm? Cycle power on the servo drive. AL503 STO self-diagnostic error Trigger condition and cause An error occurs during STO self-diagnosis, which may be caused by an abnormality in the STO circuit. Checking method and corrective action N/A How to clear the alarm? Contact the distributor. AL521 Vibration elimination parameter error Trigger condition and cause Condition:
the input value for the vibration elimination parameter is not appropriate. Cause: 1. Your input value for the vibration elimination parameter is not appropriate. 2. The Bode plot is in error due to other variables while the operation system is analyzing the program. Checking method and corrective action Perform system analysis again and correctly set the value for the vibration elimination parameter. How to clear the alarm? 1. Perform system analysis again and correctly set the value for the vibration elimination parameter. 2. If the issue persists, disable the vibration elimination function by setting P2.094 [Bit 8] and [Bit 9] to 0.
AL555 System failure Trigger condition and cause Servo drive DSP is in error. Checking method and corrective action If this alarm occurs, send your servo drive directly back to Delta without making any modification. How to clear the alarm? N/A