14 Maintenance Table 13. NOTICE: If the concentration of antifreeze is too low, there is a risk of corrosion or cavitation in the cooling system. NOTE: When topping off, use only a pre-prepared coolant mixture containing a 50% concentration by volume of corrosion-inhibiting antifreeze. 3. Check the coolant level and add more coolant if necessary. 4. Close and tighten the cap on the surge tank. 14.9 Coolant Flushing and Changing WARNING: HOT COOLANT To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots).
Remove the cap slowly to relieve pressure. Flush and change the coolant as follows: 1. Open the cap on the surge tank slowly, to allow excess pressure to escape. Set the cap aside. 2. Open the water regulating valve for the heating system. 3. Drain the coolant from the engine. Coolant system capacity is listed in the "Coolant System Capacity" table below. a. Place a receptacle underneath the coolant drain plug. Choose one that is large enough to hold the expected quantity of coolant. 42 All information subject to change without notice. Copyright © 2019 DETROIT DIESEL CORPORATION DDC-SVC-MAN-0207 Coolant Mixing Ratio Antifreeze Protection Down to:
Water Percentage by Volume Corrosion-Inhibiting Antifreeze Percentage by Volume -37°C (-47°F) 50 50 -45°C (-49°F) 45 Maximum 55