MAN Nutzfahrzeuge Aktiengesellschaft — Fuel volume regulator

Test Fuel volume regulator Flash code: 10x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Fuel volume regulator control deviation Effect of fault: The setpoint – actual value comparison for activating the fuel volume regulator has resulted in a control deviation which has exceeded a specified time threshold. This fault results in the engine being shut down. The engine can only be restarted when the fault is no longer present and the ignition is switched off and on again once. Possible cause:

Line break, short-circuit, injection pump faulty (internal fault in regulator or stiff movement), capacitance reserve of line leading to control rod position sensor too low (see page 26) Test precondition: EDC control unit disconnected Socket box connected 37 Test Measurement Corrective measures Actuating solenoid Measure resistance at socket box across pin 15 and pin 1, pin 16 and pin 2 Setpoints: 0.7–1.3 Ω Measure resistance at socket box be- tween pin 18 and pin 1 Setpoint: > 10 MΩ – Check lines – Check plug connections – If no fault found, replace injec- tion pump