MAN Nutzfahrzeuge Aktiengesellschaft — Charge-air temperature sensor

Test Charge-air temperature sensor Flash code: 1x long, 1x short Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: Charge-air temperature sensor Effect of fault: The substitute value provided in the control unit for such cases results in a reduction in power output (e.g. in the event of radiator contamination or failure of cooling system). Possible cause: Line break, short-circuit, turbo air temperature sensor defective, control unit defective, failure or contamination of cooling system. Test precondition:

EDC control unit disconnected / connected Socket box connected 39 Test Measurement Corrective measures Sensor resistance (control unit disconnected) Measure resistance at socket box across pin 34 and pin 13 Setpoint: 1.3–3.6 KΩ at 15–30°C – Check lines – Check plug connections – Replace temperature sensor – Check cooling system – If no fault found , repl ace cont rol unit (only disconnect the control unit once the current is switched off) Sensor voltage (control unit connected) Measure voltage at socket box across pin 34 and pin 13 Setpoint: 4.17–2.62 V at 10–50°C