MAN Nutzfahrzeuge Aktiengesellschaft — Undervoltage

Test Undervoltage Flash code: 1x long, 3x short Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: Control unit power supply (battery voltage too low) Effect of fault: The EDC system or the engine can behave in various ways depending on the magnitude of the voltage drop: No power Highly irregular engine operation No engine operation Excessive smoke emission Contradictory fault memory entries Possible cause: Battery discharged or faulty, alternator faulty, line break, short-circuit, main relay faulty Test precondition:

EDC control unit disconnected Socket box connected “Ignition” switched on 40 Test Measurement Corrective measures Voltage supply To activate the main relay K1, connect jumper across pin 46 and pin 19 Measure voltage at socket box across pins 15/16 (+) and pins 18/19 (–) Setpoint: 24–28 V – Check lines – Check plug connections – Replace main relay