Rating data sheet 7. Immunity to interference Pulses in accordance with ISO 7637-2 are permitted on the batt+/batt– line if they are within the fol- lowing rated values. The control unit can switch off as a precautionary measure in the case of supply voltages outside the range 7V U-Bat+ 32V. The function is resumed on returning to the permissible voltage range. 7.1 ISO pulses 1 to 4 7.2 ISO pulse 5 (load dump) Vs = 57 V Ri = 2 Ω td = 200ms (at +U-Batt = 28V) Set-up temperature Ta 65 ° C Minimum wait time between subsequent pulses 1 min Ambient air Tu 65 ° C Number of pulses 10 Voltage limitation by the internal load dump feature cuts in at min. 34 V.
7.3 EMV 7.3.1 Irradiation immunity Frequency range 1 MHz ... 1000 MHz (measure up to 400 MHz) Field strength 100 V/m sinusoidal, non-modulated (stripline measurement) Criterion Engine overrevving or shutting down not permitted. Accuracy deviation permissible. 7.4 Interference suppression In accordance with VDE 0879 Part 3, interference suppression level 2. 61 Test pulse Vs [Volt] Ri [Ohm] tl [s] Number of pulses Test duration [h] 1a –200 10 5 5 000 – 2 +100 10 0.5 5 000 – 3a –200 50 100µ – 1 3b +200 50 100µ – 1