4.9 Service procedure Maintenance Every 1000 hours service Check tightening parts of turbocharger Please contact your KOMATSU distributor to have the tightening portions checked. Check alternator driving belt tension and replacement Since inspection and replacement of the fan belt require special tools, contact your KOMATSU distributor. REMARK The machine is equipped with an auto tensioner, so there is no need to adjust the tension. If the alternator drive belt is in the following condition, the belt must be replaced. Please ask your KOMATSU distributor to replace the belt. 3 4 ! When horizontal scratch (1) crosses vertical scratch (2) !
When there are tears (3) in part of the belt 2 In case (4) where there are horizontal scratches only, there is no need to replace the belt. 1 GK032293 Replace corrosion resistor cartridge 1. Close a valve (1) of the corrosion resistor at two points. 2. Using a filter wrench, turn cartridge (2) to the left to remove it. 1 3. Apply engine oil to the sealing surface of a new cartridge, then install it to the filter holder. 2 4. Bring the packing surface into contact with the seal surface of the filter holder, then tighten it further approx. 2/3 turn. 5. Open a valve (1) of the corrosion resistor at two points. GK038120 WA380-6H – VEAM440100 4-75