TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-7 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 14 15 16 17 18 19 Before Before Before During Before After Before After Before Check Compressor Air Cleaner Service Indicators (1) Check ENGINE AIR FILTER AND COMPRESSOR AIR FILTER service indicators located on compressor instrument/control panel. The flag in a service indicator should show green. (2) If flag shows red, service or replace filter element(s). NOTE:
Ensure that access door is closed securely after inspection is complete. Check Compressor Fuel/Water Separator Check Rock Drill Dust Collector Filters Inspect Boom, Bucket, Arm, Cylinders, and Hoses for Bent, Broken, Loose, Leaking, or Missing Parts Check Track and Ground Under Machine and Propel Motors for Evidence of Leaks (1) Inspect track for missing or damaged parts. (2) Look for evidence of leakage. Inspect Hydraulic Oil Pump WARNING: Prevent possible injury from door closing. Secure door in the OPEN position. To hold door open, remove rod from stored position (A) and insert in tab (B) on door.
Flag does not show green Damaged or clogged filters Any damage that will prevent operation Any Class III leak eviden Any damage that will prevent operation Any Class III leak eviden