Komatsu — eebm001902 a3.pdf

TESTING AND ADJUSTING SOLENOID VALVE OUPUT PRESURE Table 2 # Operation of solenoid valve ON: Continuous (oil pressure generated) OFF: Not continuous (oil pressure: 0) # Check at the same time that the solenoid is switched ON/OFF electrically with monitoring code 23. # The measurement conditions in the table show the typical conditions for measuring the output pressure. # The solenoid valve may be actuated (ON/OFF) even under conditions not listed for measurement condi- tions. When operating the levers, operate them slightly (not enough to make the machine move).

20-43 Name of solenoid Measurement conditions Operating conditions Condition of solenoid Oil pressure Mpa (kg/cm2) Remarks 1 Swing brake solenoid Swing or work equipment lever operated Brake cancelled ON Min 2.74 (Min 28) All levers except travel at neutral (5 sec.

after returning to neutral) Brake cancelled OFF 0 (0) 2 Travel speed solenoid Travel speed switch at Hi or Mi, engine speed 1500 rpm or above, travel lever operated Travel speed Hi ON Min 2.74 (Min 28) Motor swash plate angle at minimum Travel speed switch at Lo or engine speed below 1500 rpm Travel speed Lo OFF 0 (0) Motor swash plate angle at maximum 3 2-stage relief solenoid Swing lock switch ON + work equipment lever operated Pressure rise ON Min 2.74 (Min 28) All levers at neutral Normal pressure OFF 0 (0) 4 Active mode solenoid Active mode OFF Normal pressure ON Min 2.74 (Min 28) Active mode ON Pressure rise OFF 0 (0) 5 Pump merge- divider solenoid Travel operated independently Flow from front and rear pumps divided ON Min 2.74 (Min 28) LS pump merge- divider valve actuated at same time Lever at neutral, or boom, arm, bucket operated independently Flow from rear pumps merged OFF 0 (0)