DISASSEMBLY AND ASSEMBLY TRACK SHOE 6. Install ring (3). 7. Using push-pull scale h , check that roller rotates smoothly. 8. Fit 0-ring and install cover (2). 9. Using tool L4 , apply standard pressure to roller oil filler port, and check for leakage of air from seal. # Standard pressure: 0.1 MPa (1 kg/cm 2 ) # Method of checking The standard pressure shall be maintained for 10 seconds and the indicator of the gauge shall not go down. 10. Using tool L4 fill carrier roller assembly with oil, then tighten plug (1). Carrier roller oil: 450 - 500 cc (E030-CD) Plug: 14.7 + 4.9 Nm (1.5 + 0.5 kgm) 30-81