Komatsu — eebm001902 a3.pdf

DISASSEMBLY AND ASSEMBLY CONTROL VALVE CONTROL VALVE Removal Run the engine at low idling, operate the cylinder to the end of its stroke without relieving the circuit, then lower the work equipment to the ground. For details, see TESTING AND ADJUSTING, Releasing pressure in hydraulic circuit. Stop the engine. Loosen the oil filler cap slowly to release the pressure inside the tank. Operate the control levers several times to release the pressure in the accumulator. Start the engine and run at low idling for approxi- mately 5 seconds, then stop the engine and operate the control levers. Repeat the above operation sev- eral times to release the remaining pressure com- pletely. 1.

Open engine hood, and remove valve top cover (1) and air cleaner top cover (2). 2. Remove partition plate covers (3) and (4) between en- gine and control valve, move partition plate cover (5) under intake hoses towards engine. 3. Disconnect 2 connectors (6) of pressure sensor and remove from holder. 4. Disconnect pump discharge hoses (7) and (8), and re- move hose clamp (9). 5. Remove self-reducing pressure valve (10). # The length of the mounting bolts is different. Left side mounting bolts (2 bolts): L=120 mm. Right side mounting bolts (2 bolts): L=125 mm. 30-89