This completes the flushing. Before starting operations, do.the following. 1. Check the level of contamination of the oil. structions given, the contamination should be (If the flushing is carried out according to the in- within the standard, but for safety and to provide contamination.) data for future reference, measure the level of later, but if they are not within the standard range, The results of the measurement are not know until carry out flushing again. 2. Replace the special flushing element with the stand- ard parts (07063-01210 x 41, and replace the flush- ing plates (21T-60-13730 x 4) with the valve and the element is replaced, replace the O-rings of the strainer.
Be sure not to forget this operation. If 4), then tighten the cover. return filter case with new parts (~07000-05175 x Condition of element when installed: - -_* -- .* 1 Fig. 1 Correct installation -_ : . . 8: Fig. 2 Incorrect installation Precaution: bottom resting on the stepped part at the bottom of Be careful not to assemble the element with the the case as shown in Fig. 2. When there is oil inside the filter case, it is particu- correctly, so after inserting the element, rotate it larly difficult to judge if the element is assembled by hand and check that it rotates smoothly. If it rotates smoothly, it can be considered that it is installed correctly. 3.
Releasing pressure from hydraulic circuit. ing to process No. E-7 (See page 106). Release the pressure from hydraulic circuit accord- 114