Komatsu — E-12: INSTALLATION OF BOOM CYLINDER HOSES

E-l 2: INSTALLATION OF BOOM CYLINDER HOSES Precautions 1) Keep the flanges, O-rings, and heads used during transportation in a safe place so that they can be used again. 2) When connecting the hoses, be careful not to get the O-rings caught. 3) When connecting the hoses, be extremely careful not to let any dirt or dust get into the circuit. 1. Remove the blind plugs in the tube at the boom cylinder end. 2. lnstal the flushing short circuit to the standard circuit (as shown in the diagram below), then re- place the O-rings (% 07000-13048 x 2, % 07000- 13038 x 2) at the hose mount with new parts. (Be careful not to twist the hoses when installing.) Boom seen from below 116