Doosan DX140R/DX140LCR — Change Oil in Travel Reduction Device (One on Each Side of Unit)

Change Oil in Travel Reduction Device (One on Each Side of Unit) 3 2 WARNING 1 The gear oil is very hot after the machine has been operating. Shut all systems down and allow them to cool. AVOID DEATH OR SERIOUS INJURY Before removing the motor case, loosen the plug slightly to allow pressurized air to escape. Residual pressure in the travel reduction device can cause the plug to be dislodged and oil to squirt out suddenly. Figure 85 FG028680 FG028809 NOTE: Drain oil after first 500 hours of operation or rebuild, and every 1,000 hours thereafter. 1. Make sure that the machine is on firm and level ground. 2.

Rotate the track until ports (1 thru 3, Figure 85) are in their proper positions as shown. 3. Place a container under drain plug (2, Figure 85) and remove plugs (1 thru 3) to drain the travel reduction gear oil. NOTE: Dispose of drained fluids in compliance with all applicable environmental laws and regulations. 4. Install drain plug (2, Figure 85). Refill the travel reduction gear case with fluid through fill port (3) until fluid level is at port (1). Install level plug (1) and fill plug (3). NOTE: See "Fluid Capacities" on page 4-9 for capacity. 5. Repeat this procedure on the other travel reduction device.

DX140R/DX140LCR Inspection, Maintenance and Adjustment 4-50 Reference Number Description 1 Oil Level Plug 2 Drain Plug 3 Fill Plug