Doosan DX140R/DX140LCR — Change Swing Reduction Device Oil

Change Swing Reduction Device Oil NOTE: Change swing reduction device oil after first 500 hours of operation or rebuild and every 1,000 hours thereafter. 2 1 WARNING AVOID DEATH OR SERIOUS INJURY FG009555 Figure 86 The gear oil is very hot after the machine has been operating. Shut all systems down and allow them to cool. 1. Set a container under excavator. 2. Remove cap (3, Figure 87) and install hose (4) to drain the swing reduction device oil. NOTE: Dispose of drained fluids in compliance with all applicable environmental laws and regulations. 3 3. After draining oil, remove hose and install cap. FG009556 Figure 87 4.

Remove breather/fill cap (2, Figure 86) and add oil to "H" mark on dipstick (1). L H FG000419 Figure 88 Inspection, Maintenance and Adjustment 4-51 DX140R/DX140LCR