Hydraulic Oil Exchange and Suction Strainer Cleaning WARNING AVOID DEATH OR SERIOUS INJURY The hydraulic oil will be hot after normal machine operation. Allow the system to cool before attempting to service any of the hydraulic components. Figure 108 ARO1760L The hydraulic tank is pressurized. Loosen the breather cap to allow the pressurized air to vent. After the pressure has been released, it is safe to remove either the fill cap or service covers. IMPORTANT Make sure to clean any dirt or water from the top of the hydraulic tank, especially around the fill port and filter ports. Hydraulic oil change interval is 2,000 hours, only when DOOSAN Genuine Oil is used.
If another brand of oil is used, guaranteed change interval is 1,000 hours. NOTE: Based on the type of excavating being completed, the working conditions (extremely hot or dusty) and the extra front end attachments being used (hydraulic breaker, etc.), the hydraulic fluid will need to be changed more frequently. 1. Park machine on firm and level ground. Swing upper structure parallel to tracks. Lower boom and position bucket on ground as shown in Figure 109. 2. Move safety lever to "LOCK" position. 3. Stop engine. 4. Release pressurized air from hydraulic tank by rotating breather cap (1, Figure 112). EX1300561 Figure 109 DX140R/DX140LCR Inspection, Maintenance and Adjustment 4-60