Komatsu — AIR CLEANER ELEMENT-CHECK/CLEAN/REPLACE

MAINTENANCE MAINTENANCE PROCEDURE Machines Equipped With Double Element (If equipped) Checking Whenever the red piston in dust indicator (1) appears, clean the air cleaner element. NOTICE Do not clean the air cleaner element before the red piston in dust indicator (1) appears. If the air cleaner element is cleaned frequently before the red piston in the dust indicator appears, the air cleaner cannot provide the proper performance and the cleaning efficiency is lowered. Cleaning or replacing outer element 1. Open the engine food on the rear of the machine, remove wing nut (2) and take out element (3) . 2. Clean interior of the air cleaner body. 3.

Direct dry compressed air (less than 0.69MPa(7 kgf/cm 2 , 99.4 PSI)) to element 3 from inside along its folds, then direct it from outside along its folds and again from inside. 1) Remove one seal from the element whenever the element has been cleaned. 2) Replace the outer element if it has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. 3) Replace both inner and outer elements when the dust indicator red piston appears soon after installing the cleaned outer element even though it has not been cleaned 6 times. 4) Check inner element mounting nuts for looseness and, if necessary, retighten.

Tightening torque:4.9 to 5.88 N•m(0.5 to 0.6 kgf•m, 3.6 to 4.3 lbft) 4-21