Detroit Diesel — Print Preview - C:\Temp\APTCACHE\6SE412A\6SE412A Detroit Diesel

MBE 4000 SERVICE MANUAL 4. Assemble the EGR reed valve housing flange, cooler intermediate flange, gasket and front sheet metal support together. Attach all to the cooler housing using the eight mounting bolts. Torque the bolts to 10 N·m (8 lb·ft). See Figure 7-29. 1. EGR Cooler-to- Sheet Metal Support Bolts 2. EGR Cooler Flange Bolts Figure 7-29 Installing the EGR Cooler Flange 5. Attach the EGR cooler to the front sheet metal support with two bolts. Torque to 25 N·m (19 lb·ft). See Figure 7-29. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 7-37