MAINTENANCE MAINTENANCE PROCEDURE CHECK OIL LEVEL IN DAMPER CASE, ADD OIL WARNING The parts and oil are at high temperature after the engine is stopped, and may cause serious burns. Wait the temperature to go down before starting the work. NOTICE For the oil level check, park the machine on a flat ground and start the work more than 30 minutes after the engine was stopped. 1. Open the cover on the right side of the machine. 2. Remove oil inspection plug (G) and check that the oil is near the bottom of the check hole.
If the oil level is low, remove the plug from oil filler (F), and add oil through oil filler (F) until the oil level is close to the bottom of the hole of oil inspection plug (G). NOTICE If the oil level is found too high, be sure to drain the oil to the specified level. The excess oil may cause overheating. 3. Install oil inspection plug (G) and the plug of oil filler (F). 4. Close the cover. CHECK ALL TIGHTENING PARTS OF TURBOCHARGER Contact your Komatsu distributor to have the tightening portions checked. CHECK PLAY OF TURBOCHARGER ROTOR Ask Komatsu distributor to check the play of the turbocharger rotor.
CHECK FAN BELT TENSION AND REPLACE FAN BELT Special tools are required for inspection and replacement of the fan belt. Contact your Komatsu distributors for inspection and replacement. REMARK An installed auto fan belt tension adjuster, "Auto Tensional Fan Belt", dispenses with the belt deflection adjust- ment. 4-65