4. Install the cover plate and gasket over the pressure control spool. See Figure 4-477. Install the bolts and tighten to 25 Nm (18 ft lb). 7. Place the gasket and cover plate over the relief valve and sequence valve. See Figure 4-480. Install the screws and tighten to 10 Nm (8 ft lb). FIGURE 4-477 4915 FIGURE 4-480 4918 5. Insert the dowel, springs, and pressure relief spool into the valve bore. See Figure 4-478. 8. Install a new O-ring on the solenoid valve. See Figure 4-481. Insert the solenoid valve into its bore. Install the bolts into the solenoid valve and tighten to 10 Nm (8 ft lb). FIGURE 4-478 4916 6. Install the sequence valve into the valve bore. See Figure 4-479.
FIGURE 4-481 4919 FIGURE 4-479 4917 Mega 300-III Shop Manual TORQUE CONVERTER AND TRANSMISSION 4-111