Automatic Bucket Return-to-Dig System This powers a relay that activates the bucket return-to-dig function and also holds the pilot valve lever in the boom raise mode. As the boom continues to rise, and the bucket becomes parallel with the ground, the boom proximity switch is tripped OFF. This causes the pilot valve lever to return to the NEUTRAL position, and the bucket remains parallel with the ground. If the operator now moves the pilot valve lever to the boom lower position, the boom will lower to the ground and the bucket will already be in the dig position.
This system automatically returns the bucket to a level position (the dig position), to reduce cycle time and to reduce operator effort. When the bucket is on the ground, putting the lever in the RAISE position will raise the boom, and therefore the bucket. As the boom rises, the boom proximity switch is tripped ON. See Figure 7-75. FIGURE 7-75 5014 7-24 HYDRAULIC SYSTEM Mega 300-III Shop Manual