Automatic Boom Kick-out System Automatic Boom Float System When the pilot valve lever is in the HR position, this locks the boom into continuously raising. If the boom were allowed to rise to the maximum exten- sion of the boom raising cylinders, there would be a certain amount of shock to the cylinders as they bottomed out, and the pump would then force oil over the relief valve. This would cause the oil temperature to rise. To prevent the shock and high temperature, the boom kick-out system stops the boom from rising before the point of maximum cylinder extension is reached.
When the pilot valve lever is shifted to the float position, the lever is locked and oil from the pilot pump flows into the pilot valve and is directed to the boom spool. The float separation piston in the spool moves to the right and the boom spool moves to the float position. The contacts in the boom float proximity switch move to the OFF posi- tion and direct current through the float kick-out relay to lock the lever solenoid in the boom float position. If an attempt is made to float the boom when the boom is on the ground, the contacts in the boom float proximity switch are tripped to the ON position and this cuts off current to the lever solenoid.
When the pilot valve lever is operated to lift the boom off the ground, the raise kick-out proximity switch is tripped and reset to OFF. See Figure 7-75. This directs current through the float and raise kick- out relays and locks the pilot valve lever solenoid in the boom raise position. As the boom continues to rise it will reach a position where it trips the raise kick-out proximity switch to the ON position. This cuts off current to the pilot valve lever solenoid and this stops the boom from raising any farther.
If the pilot valve lever is operated when the bucket is being positioned by the return to dig system, loader pump output is directed to to the bucket cylinder and pressurized oil in the boom cylinder returns to tank. Mega 300-III Shop Manual HYDRAULIC SYSTEM 7-25