Hydraulic Full Flow Filter Replacement The hydraulic full flow oil filters (2) must be changed after the first 50 hours of operation to comply with the new machine break-in require- ments. After the first change, the filters must be changed every 250 hours. 9. Set the cover (2, Figure 3-23) into place over the element (6). Install the bolts (1) through the cover (2) and tighten them. 10. Tighten the breather cap on the reservoir. 1. Loosen the breather cap on the hydraulic reservoir. See Figure 3-15. Check Fan Belt Tension The fan belt tension must be checked after the first 50 hours of operation to comply with the new machine break-in requirements.
After the first tension check, the belt must be checked every 150 hours. Apply 10 kg (22 lb) of force to the midpoint of the fan belt. See Figure 3-24. The fan belt should deflect 10 mm (0.4"). If the belt deflects more than this, loosen the control link and move the idler pulley (2) to tighten the belt tension until deflection is 10 mm. Inspect the fan belt for damage. If the belt is damaged, replace it. 2. Clean the filter cover (2, Figure 3-23) and the reservoir around the cover. 1. Bolt 2. Cover 3. Spring 4. O-ring 5. Valve 6. Element 7. Strainer 8. Bolt 9. Cover 1. Fan Pulley 2. Idler Pulley 3.
Crank Pulley FIGURE 3-24 2838 Clean Exterior of Radiator and Oil Cooler Dust and dirt accumulation on the fins of the radi- ator and oil cooler greatly reduce their cooling efficiency. Use water and steam to clean the fins on the radiator and oil cooler. On an especially dusty job site, clean the fins every 50 hours. On other job sites, clean the fins every 500 hours. Figure 3-23 2045 3. Remove the bolts (1, Figure 3-23) from the cover (2). 4. Lift the cover (2) and O-ring (4) off the reser- voir. Control the spring (3) that sits beneath the cover. Remove the spring (3). 5. Remove the valve (5) and the filter element (6) from the reservoir. 6. Clean the underside of the cover (2). 7.
Set a new element (6) and valve (5) down into the reservoir. Press the element down onto its base until the top of the element is approxi- mately 4 mm (0.157") below the edge of the reservoir. 8. Install a new O-ring (4) on the cover (2). Set the spring (3) into place on the element (6). MEGA 300-III Shop Manual INSPECTION, MAINTENANCE AND ADJUSTMENT 3-11