Every 250 Operating Hours 2. Remove the O-ring (3, Figure 3-26) and the filter element (2). Perform All Daily and 50 Hour Service Checks 3. Use a non flammable, non-toxic solvent to clean out the cover (1). Hydraulic System Pilot Filter Replace the filter element in the pilot filter. See Figure 3-25. Perform the following steps. 4. Insert a new filter element (2) into the cover (1). Install a new O-ring (3). 5. Thread the cover (1) onto the filter head (4). Clean Air Cleaner CAUTION!!! Never remove the air cleaner element while the engine is running. This will allow dirt to be sucked into the engine and cause serious engine damage. Always turn the engine off before servicing the air cleaner.
Remove the air cleaner element and clean it with compressed air. See Figure 3-27. Inspect the element. If any holes or damage are present, replace the element. If the element does not become damaged, it must be replaced every 1,500 hours. FIGURE 3-25 2047 1. Unthread the element cover (1, Figure 3-26). The cover is filled with oil. Dispose of the oil. 1. Cover 2. Element 3. O-ring 4. Head 5. Bypass Valve FIGURE 3-27 2839 FIGURE 3-26 0099 3-12 INSPECTION, MAINTENANCE AND ADJUSTMENT MEGA 300-III Shop Manual