24. SERVICE PROCEDURE If the top of a battery is dirty, it may be cleaned with a brush dipped in ammonia or soda solution. The vent plugs must be tightened and sealed to prevent any solution from getting into the battery cells. After the foaming stops, flush off the battery with clean water and unseal the vent plugs. Brighten the terminal contact surfaces with steel wool or a stiff brush. 24.11.2.5.4 Liquid Level - Conventional Battery The electrolyte in each cell must be at the proper level, 6 to 13 mm (% to % in) above the plates, at all times to prevent battery failure. Check the level of the electrolyte. When the electrolyte is below this level, pure distilled water must be added.

Never use hydrant water or any water which has been in a metal con- tainer. Acid or electrolyte must never be added except by a skilled battery man. Under no circumstances add any special battery solutions or powders. It is especially important to keep the battery at full charge for cold weather operation. Add distilled water to the battery in freezing temperatures only when the engine is to operate for several hours, to thoroughly mix the water and the electrolyte, or damage to the battery may occur. 24.11.2.5.5 Charging Fully Discharged Maintenance-Free Battery When a machine is not in use for an extended period, the maintenance-free battery can become discharged.

For this reason, when a machine will not be used for over 30 days, it is recommended that the negative ground terminal cable be disconnected. Prior to starting up a machine that has been idle, always make a visual inspection of the battery and take an open circuit voltage test. A reading of 12.3 volts (65% of full charge) or less indicates a state of discharge. The open circuit voltage test should be taken after removing the surface charge. This is accomplished with a draw of 300 amps for 15 seconds. Wait for a couple of minutes, then check the open circuit voltage.

The point to remember is the lower the open circuit voltage, the longer it will take before the battery begins to accept a measurable amount of charge. Charge the battery until a minimum open circuit voltage of 12.4 volts is reached. Then test the battery. If an open circuit voltage reading of 12.4 volts is not attained at the end of 12 hours, it can be assumed that the battery has failed. If the voltage does not drop below 9.6 volts at 21 “C (70°F) for the duration of the load test, the battery is good. 3-60