Chapter 11 TPD1317e Page 72 Model M225Ti/M215C Model M185C Exhaust Exhaust gas flow 35.08 m3/min (1240 ft3/min). Maximum restriction measured within(305 mm) 12” of turbocharger outlet. 10.2 kPa (3.0” Hg) Recommended pipe bore (wet exhaust). 127 mm (5.0”) 100 mm (4.0”) Recommended pipe bore (dry). 76.2 mm (3.0”) Minimum rise from sea water level to exhaust outlet centreline. 203 mm (8.0”) Lubricating System Recommended lubricating oil. AP1 CD/SE CCMC D4 Sump capacity maximum 15 litres (3.3 gallons) Maximum installation angle plus planing angle for continuous operation. 17o engine front up + 3o rise. 5o nose down + 3o rise with special kit of parts, 30o heel when motor sailing.
Oil pressure, in operating speed range (steady state). 2.8 to 3.8 bar (40 to 55 psi) Low oil pressure switch setting. 0.8 bar (12 psi) Electrical System Alternator Lucas A127 40A (24V) or 70A (12V). Starter type Lucas S115 Number of teeth in flywheel 126 Number of teeth on starter 10 Cold Start Limits Minimum cold start temperature (with aid). -15oC (5oF) Batteries for minimum 2 off - 12V 315 Amps to BS3911 or cold start 2 off - 12V, 535 amps to SAE J537