3.3 Operation Operation The time that the preheating pilot lamp (2) stays lighted up depends on the ambient temperature as shown in the table on the right. Ambient temperature Lighting time -1°C to -15°C 0 seconds to 30 seconds -15°C or less 30 seconds 2. If the preheating pilot lamp (2) does not light up, or it lights up and then goes out to inform that the engine preheating has been completed, turn the key in starting switch (1) to the START position (C). A B 3. The starting motor will continue to turn and the engine will start. Keep the key in starting switch (1) at the START position (C) to keep the starting motor running until the engine starts.
C REMARK In low temperatures, to ensure lubrication of the engine and to improve the durability, no fuel is supplied to the engine for 3 sec- onds after the key in starting switch (1) is turned to the START position (C), so the engine will not start during this time. Therefore, keep the key in starting switch (1) at the START posi- tion (C) to keep the starting motor running until the engine starts. GK038021 4. After the engine starts, release the key in starting switch (1). The key will automatically return to the ON position (B). A B 5. After the engine starts, if the engine water temperature is low (below 20°C), the warming-up operation (engine speed:
1020 rpm) is automatically carried out. 6. For details, see "Automatic warming-up operation (3-109)". C REMARK Keep the accelerator pedal depressed after the engine starts up, until engine warming-up run is finished. Do not step on the pedal to the full stroke. GK038021 REMARK Immediately after the engine is started, the turbo protect function is actuated. Even if the accelerator pedal is depressed, the engine speed will not rise above 1,000 rpm. Engine water temperature Turbo protect time The turbocharger rotates at extremely high speed.
Immediately after the engine is started, the pressure of the lubricating oil has not risen sufficiently, so if the engine speed is suddenly raised, it may lead to damage or seizure of the turbocharger bearing. The turbo protect function acts to prevent this problem. It uses elec- tronic control to prevent the engine speed from rising above a certain speed for the first few seconds after the engine started. above 10°C 0 sec. below 10°C 0 to 20 sec. 3-106 WA470-6H – VEAM946100