Operation 3.3 Operation Lift arm operation Set the work equipment lock lever to the FREE position before operating the control lever. c d NOTE Do not use the FLOAT position when lowering the bucket. Use the FLOAT position when leveling, see "Leveling operation (3-134)". a b Position (a): RAISE When the lift arm control lever is pulled further from the RAISE position, the lever is stopped in this position until the lift arm reaches the preset position of the kickout, and the lever is returned to the HOLD position. GK038040 Position (b): HOLD Raise The lift arm is kept in the same position. Position (c): LOWER Position (d): FLOAT Lower The lift arm moves freely under external force.
GK032142 Bucket operation Set the work equipment lock lever to the FREE position before operating the control lever. Position (a): TILT When the bucket control lever is pulled further from the TILT position, the lever is stopped in this position until the bucket reaches the preset position of the positioner, and the lever is returned to the HOLD position. c b a Position (b): HOLD The bucket is kept in the same position. Position (c): DUMP GK038039 Tilt Dump GK032144 WA470-6H – VEAM946100 3-129