John Deere Radial Piston Pumps (3000 Series) — John Deere Radial Piston Pumps (3000 Series) User Manual

GTM-7 (5-89) 2R3; 015 IB 110589 AWl :R39600 R70: 070300 989 290188 AW1:R39601 R70;070300 990 290188 3000 Series (HPR)-HydrauHc Pump Litho in U.S.A. 15-18 IMPORTANT: DO NOT use grease to hold needle rollers. Doing so can restrain roller movement and cause pump failure. Use only clean hydraulic 011. IMPORTANT: Fixed spacers on double bank pump are installed only after races are installed on pump shaft. One fixed spacer is used between each race and taper roller bearing. 2. Install first row needle rollers (25 used) on shaft journal using a rubber band to aid installation. 3. Install race with thrust washers onto pump shaft sliding race over first row needle rollers.

Pull rubber band over race as race slides over needle rollers. 4. Install middle spacer in race and second row of needle rollers (25 used). 5. Install third spacer over second row of needle rollers. IMPORTANT: Taper roller bearings must be pressed onto pump shaft even if shaft has not been disassembled. This assures correct pump shaft end play. 7. Press bearing cones against pump shaft journal making sure fixed spacer aligns properly with slot in shaft journal. ASSEMBLE PUMP SHAFT 6. Install fixed spacer on pump shaft. 1. Put spacer on pump shaft. AllTractorManuals.com