Litho in U.S.A. 10-14 CTM-7 (5-89) 2R3; 010 14 110589 2000 Series (PRJ-Hydraulic Pump 6. Pry upward on vice grips using a long (3/4 in. minimum) box-end wrench noting indicator reading. If end play is more than specification, check bearings for wear. Acceptable 0.025-0.100 mm (0.001--0.004 In.) 7. Increase number or size of shims in pressure compensa- tor housing on single bank or secondary housing on double bank pump to obtain correct specification. END PLAY SPECIFICATION 5. Zero the indicator. AllTractorManuals.com